CBB61 AC motor capacitor (plastic case)
Outline Drawing
Features
Widely applied to the starting and running of AC single-phase motors at 50Hz/60Hz frequency power.
Self-healing property
Good stability and reliability
Specifications
Reference standards | GB/T 3667.1( IEC60252-1) |
Climatic category | 40 / 70 / 21、40 / 85 / 21 |
Class of operation | Class B (10000h) Class C (3000h) |
Class of safety protection | S0 /S3 |
Voltage range | 250VAC、370VAC、440VAC、450VAC |
Capacitance range | 1~35μF |
Capacitance tolerance | ± 5% 、 ± 10%、± 15% |
Dissipation factor | 20 x10-4 (100Hz,20°C) |
Test voltage terminal to terminal UTT | 2Un for 2 seconds |
Test voltage terminal to case UTC | (2Un+1000)VAC or 2000VAC- 50Hz for 60 seconds |
Insulation resistance | ≥3000s (100Hz,20°C,1min) |
Dimensions(mm)
Specifications | 450VAC | 250VAC |
1μF | 37×13×23 | 37×13×23 |
1.2μF | 37×13×23 | 37×13×23 |
1.5μF | 37×14×25 | 37×13×23 |
2μF | 37×16×28 | 37×13×23 |
2.5μF | 37×18×28 | 37×14×25 |
3μF | 47×18×29 | 37×14×25 |
3.5μF | 47×18×34 | 37×16×28 |
4μF | 47×18×34 | 37×16×28 |
4.5μF | 47×22×34 | 37×16×28 |
5μF | 47×22×34 | 37×18×28 |
5.5μF | 47×22×34 | 37×18×28 |
6μF | 47×22×34 | 47×18×29 |
6.5μF | 48×26×38 | 47×18×29 |
7μF | 48×26×38 | 47×18×29 |
8μF | 48×26×38 | 47×18×34 |
10μF | 58×26×44 | 47×22×34 |
12μF | 58×26×44 | 47×22×34 |
15μF | 58×26×44 | 47×22×34 |
16μF | 58×26×44 | 48×26×38 |
20μF | 58×35×49 | 48×26×38 |
25μF | 58×35×49 | 48×26×38 |
30μF | negotiable | 58×26×44 |
35μF | negotiable | 58×26×44 |
Note: Other specifications、size and terminal outside table are negotiable.
The reliability of capacitors depends not only depends on the reliability factors of the capacitor itself, but also on correct selection and reasonable use, to ensure that the product can achieve the intended use and reliability for users' reference.
Ordering or requesting samples,please try to provide the following information if possible :
1. Application: e.g. UPS, transducer, rectifier etc.
2. Rated capacitance and tolerance
3. Voltage: including rated voltage, working voltage, ripple voltage, non periodic impact voltage etc.
4. Current: including maximum current, working current, maximum peak current, maximum impact current etc.
5. Frequency: including working frequency, pulse Frequency, ripple voltage frequency etc.
6. Working place: e.g. fixed place, vehicles, ships etc.
7. Working environment: e.g. temperature range, humidity, altitude etc.
8. Product dimensions: e.g. diameter, height or length, width, height etc.
9. Terminal type: e.g. Bolt type, screw hole type etc.
10. Safety requirements: e.g. flame retardant, anti-explosion etc.
11. Life expectancy: under given working conditions.
12. Installation: e.g. bottom-stud, middle-clip, mounting ears etc.
13. Others